Lean Six Sigma 100%

Yellow Belt · Measure phase

Lesson 7: Trusting the measurement (Measurement System Analysis and Gage R&R)

IASSC Body of Knowledge 2.3, Measurement System Analysis · 14 practice questions

0:00 / --:--

Reading

Every conclusion a Six Sigma project draws rests on measured data. If the measurement system producing that data cannot be trusted, nothing built on top of it can be trusted either, no matter how sophisticated the analysis gets later. Measurement System Analysis, MSA, is the discipline of verifying that a measurement system itself is fit for purpose before the data it produces is used to make decisions.

Accuracy versus precision, shown as four shot groups on a target Accurate and precise means shots are tightly clustered on the bullseye. Precise but not accurate means shots are tightly clustered but off-center, indicating bias. Accurate but not precise means shots are centered on average but widely scattered, indicating poor repeatability. Neither accurate nor precise means shots are both off-center and widely scattered. Accurate and precise Precise, not accurate (bias)
Accuracy is how close a measurement is to the true value; precision is how tightly repeated measurements cluster. A measurement system can fail either one independently, which is why Gage R&R checks repeatability and reproducibility separately from bias.

Precision and accuracy

These two words are used casually as synonyms in everyday speech but mean different things in MSA. Accuracy is how close a measurement is to the true, correct value. Precision is how close repeated measurements of the same thing are to each other, regardless of whether they are close to the true value. A measurement system can be precise but inaccurate, consistently returning the same wrong number, or accurate but imprecise, averaging out to the right number while individual readings scatter widely. A useful measurement system needs both.

Bias, linearity, and stability

Three specific properties of a measurement system are evaluated separately:

  • Bias: the difference between the average of repeated measurements and the item's known, true, or reference value. A gage that consistently reads 2 grams heavy on a known 100-gram reference weight has a bias of 2 grams.
  • Linearity: whether that bias stays consistent across the full range the gage is used over. A gage that is accurate at the low end of its range but increasingly biased at the high end has a linearity problem, and a single bias check at one point on the scale would miss it entirely.
  • Stability: whether the gage's bias and variation stay constant over time, checked by periodically re-measuring the same reference item and watching for drift. A gage that was accurate when it was calibrated six months ago but has since drifted has a stability problem, which is why gages are recalibrated on a schedule rather than checked once and trusted indefinitely.

Gage Repeatability and Reproducibility (Gage R&R)

A Gage R&R study is the standard method for quantifying how much of a measurement system's total observed variation comes from the measurement system itself, as opposed to genuine variation in the parts being measured. It separates measurement variation into two components:

  • Repeatability, sometimes called equipment variation: the variation seen when the same appraiser measures the same part multiple times with the same gage. High repeatability variation points to a problem with the equipment itself.
  • Reproducibility, sometimes called appraiser variation: the variation seen when different appraisers measure the same part with the same gage. High reproducibility variation points to a problem with how the measurement procedure is being applied, such as unclear instructions or inconsistent technique between operators, rather than the equipment.

A typical Gage R&R study has several appraisers each measure the same set of parts multiple times, in random order, without knowing which part they measured before, and the results are analyzed to see what percentage of the total observed variation is coming from the measurement system rather than from real part-to-part differences. If the measurement system itself is consuming a large share of the total variation, any conclusion drawn later from that data is suspect, because the team cannot tell how much of what it is seeing is the process and how much is just measurement noise.

Repeatability and reproducibilityRepeatability: Same appraiser, Same part and gage, Repeated measurements. Reproducibility: Different appraisers, Same part and gage, Compare measurements RepeatabilitySame appraiserSame part and gageRepeated measurementsReproducibilityDifferent appraisersSame part and gageCompare measurements
The reading separates measurement variation within an appraiser from variation between appraisers. Both use the same part and gage.

Variable and attribute MSA

The Gage R&R study described above is the standard approach for variable data, continuous measurements such as length, weight, or time, where the output is a number on a scale. For attribute data, discrete pass or fail, go or no-go, or categorical judgments, a different method is used, generally called attribute agreement analysis. Multiple appraisers classify the same set of items more than once, and the analysis checks how often each appraiser agrees with themselves across repeated trials, how often different appraisers agree with each other, and how often the appraisers, individually and collectively, agree with a known correct answer. A visual inspection process that different inspectors classify inconsistently has an attribute measurement system problem in exactly the same sense that an inconsistent gage does for variable data, and needs the same kind of fix: clearer standards, better training, or a better inspection method.

Reading and judging a %GRR result

A Gage R&R study's output is usually reported as %GRR, the measurement system's variation expressed as a percentage of the total observed variation (commonly calculated as %Study Variation, the Gage R&R standard deviation divided by the total standard deviation, times 100). Under widely used AIAG guidelines, a %GRR under 10 percent is generally considered an acceptable measurement system. A %GRR between 10 and 30 percent may be acceptable depending on the application, the importance of the measurement, the cost of the gage, and the cost of repair, and usually calls for a judgment call rather than an automatic pass or fail. A %GRR over 30 percent is generally considered unacceptable, and the measurement system needs improvement before the data it produces is trusted for decisions.

A second output, the number of distinct categories (ndc), estimates how many truly distinguishable groups of parts the measurement system can reliably tell apart across the range of parts studied. A commonly used minimum is five or more distinct categories; a measurement system below that threshold cannot reliably tell many parts apart from each other, even if its %GRR number looks acceptable on its own, which is why both figures are checked together rather than either one alone.

Practice questions

1. What is the difference between accuracy and precision?

  1. Precision measures the bias of a gage against a reference standard, while accuracy measures the repeatability of its readings
  2. They are exact synonyms with no practical difference
  3. Accuracy is closeness to the true value; precision is closeness of repeated measurements to each other
  4. Accuracy applies only to attribute data, precision only to variable data

2. A gage consistently returns the same wrong reading every time it measures a known reference part. How is this system best described?

  1. Neither precise nor consistent
  2. Precise but inaccurate
  3. Both accurate and precise
  4. Accurate but imprecise

3. A gage reads 2 grams heavy every time it measures a known 100-gram reference weight. What is this property called?

  1. Repeatability
  2. Bias
  3. Reproducibility
  4. Linearity

4. A gage is accurate at the low end of its measurement range but increasingly biased at the high end. What property is this describing?

  1. Repeatability
  2. Reproducibility
  3. Stability
  4. Linearity

5. Why are gages recalibrated on a schedule instead of checked once and trusted indefinitely?

  1. Because recalibration is required only for attribute data and is never applied to gages that measure variable data
  2. Because repeatability studies replace the need for calibration
  3. Because bias never changes once a gage is manufactured
  4. Because stability checks for drift in a gage's accuracy and variation over time

6. What does a Gage R&R study measure overall?

  1. How much of the total observed variation comes from the measurement system itself, versus genuine part-to-part variation
  2. The Risk Priority Number of a failure mode
  3. Only the cost of the measurement equipment
  4. The number of defects per million opportunities

7. In Gage R&R, what does "repeatability" refer to?

  1. The percentage of units passing a step without rework
  2. Variation seen when the same appraiser measures the same part multiple times with the same gage
  3. Variation seen when different appraisers each measure different parts, using different gages, on different days
  4. The difference between a measurement and its known true value

8. High reproducibility variation in a Gage R&R study most likely points to what kind of problem?

  1. A problem that cannot be diagnosed by MSA
  2. A problem with the reference standard's true value
  3. A problem with how the procedure is applied between appraisers, such as unclear instructions or inconsistent technique
  4. A problem with the gage's internal mechanics only, such as a worn sensor, a loose fixture, or a fault inside the instrument itself

9. What kind of data does a standard Gage R&R study apply to?

  1. Variable, continuous data such as length, weight, or time
  2. Only financial data, such as the dollar savings figures used in benefits capture on a project
  3. Only data collected during the Control phase
  4. Attribute, pass or fail data only

10. For discrete pass or fail, go or no-go judgments, which method is used instead of a standard Gage R&R study?

  1. Rolled Throughput Yield calculation
  2. A cause and effect matrix
  3. Attribute agreement analysis, checking agreement within and between appraisers and against a known correct answer
  4. A value stream map

11. GCHS uses a laser distance meter to verify wheelchair ramp lengths before final inspection sign-off. A Gage R&R study finds a total standard deviation of 0.40 inches and a Gage R&R (measurement system) standard deviation of 0.06 inches. What is the %GRR, and how should it be judged under common AIAG guidelines?

  1. 15 percent, which may be acceptable depending on application, gage cost, and cost of repair
  2. 6 percent, an acceptable measurement system because the gage variation is far below the 0.40 inch total
  3. 24 percent, an unacceptable measurement system
  4. 66 percent, an unacceptable measurement system

12. In a Gage R&R analysis, what does the number of distinct categories (ndc) estimate, and what is the commonly used minimum for a capable measurement system?

  1. The minimum number of appraisers required, generally two
  2. The minimum number of times each part must be measured, generally ten
  3. The minimum number of reference standards needed, generally three
  4. The number of truly distinguishable groups of parts the system can tell apart, with a commonly used minimum of five

13. Under common AIAG guidelines for %GRR, which range is generally considered unacceptable?

  1. Exactly 10 percent
  2. Under 10 percent
  3. Over 30 percent
  4. Between 10 and 20 percent

14. In a Gage R&R study, why do appraisers measure the sample parts in random order without being told which part they measured previously?

  1. Because random order is a requirement only for attribute agreement analysis and is never used in a Gage R&R study, where parts are always measured in sequence
  2. To prevent an appraiser from unintentionally biasing a reading by recalling or matching a previous measurement of the same part
  3. To reduce the number of appraisers needed for a valid study
  4. To make the study take less time overall

Glossary

Accuracy
How close a measurement is to the true, correct value.
Precision
How close repeated measurements of the same thing are to each other, regardless of whether they are close to the true value.
Bias
The difference between the average of repeated measurements and the item's known, true, or reference value.
Repeatability
The variation seen when the same appraiser measures the same part multiple times with the same gage.
Reproducibility
The variation seen when different appraisers measure the same part with the same gage.
%GRR
The measurement system's variation expressed as a percentage of the total observed variation.
Number of distinct categories (ndc)
An estimate of how many truly distinguishable groups of parts a measurement system can reliably tell apart.
Attribute agreement analysis
The MSA method used for discrete pass or fail or categorical judgments, in place of a variable Gage R&R study.
Back to course Next lesson